6 lead motor hook up, wye configuration high voltage

By joining you are opting in to receive e-mail. Did the wiring cause the bearing failure? Where is a good source for a transformer no electronics on this dinosuar. We are trying to connect it to V Anyone? Usual bearing failure for general purpose motors are more on grease related application problem, misalignment, russian dating photo gallery worn out bearing and loosen bearing housing.

Motor Connection Diagrams
Difference Between 4-Wire 6-Wire and 8-Wire Stepper Motors

But is necesary investigate in name plate or perform some test prior to starting in order to find the proper conection for the rated voltage. The function of a circuit breaker is to provide overload thermal and short-circuit magnetic protection to a circuit and its downstream components. Did you make this project?

Issue Details

Thread Tools Show Printable Version. Bookmarks Bookmarks Digg del. The Adafruit motor shield can run two stepper motors using four wires for each so we're going to connect white and red and orange and blue to stepper motor port to. Faulty wiring or wrong connection will trigger motor protection to trip.

6 lead motor

Star will have one star point made internally and inaccesible. It would be rated volts and be capable of being re-connected for use at volts. It's easy to join and it's free. After Brush we moved down to the south coast, and I did a short spell at Allen West before that virtually disappeared. If you don't have one, it's worth buying one as you can get one for just a few bucks nowadays, and even the cheapest one you can find is good enough for this sort of project.

Most stepper motors come with four, six, or eight wires. In this tutorial I'll show you how we can figure out how to connect the stepper motor to an Arduino and control it using the Adafruit motor shield. Well, the X, Y, Z terminals are throwing me for a loop.

Red Flag This Post Please let us know here why this post is inappropriate. There are guys way more qualified than me to answer you, but I will tell you what I have seen. Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden. As for British made motors, I'm wearing my black arm-band, all I have left is my pile of specs. This has been used in other countries too.

The Eng-Tips staff will check this out and take appropriate action. If the motor, being run with the start windings only caused it to overheat, it would also cause premature bearing failure. Run simulations on both your local machine or in the cloud. Dag S K Only small european motors are wired in star at their normal working voltage, Larger ones are often started in star then switched to delta after a preset time. Never mind, I think I got it.

6 lead single voltage motor

Learned something new today. Stardelta, any jobs up there for an old Brush bloke? As a stretch, maybe it's old, free dating sites in aruba and there has been a change to the numbering system.

6 lead single voltage motor

European 3 phase motor connections

Here are the resistances is that I measured. Here is another example application of a motor shield. Thank you guys what a great board thank you all for allowing me to be a part of it!

Monarch has a series of machines intended for handling material for that industry's unique applications. Very large spindle bores, significa much larger than the usual undersized Monarch spindles. Ran into one of my pumps that had its bearing fried. Life is much easier with only one voltage.

This motor is on a big Cincinnati Mill. Lately, I have had to hook several European - German motors. Do they just over build the coils for this purpose? This is the way it is wired now for high voltage.

Dgarland, how big is the motor? Close this window and log in. That would fit with your description as this being connected for the lower voltage.

Wye Configuration Low Voltage
IEC 9 lead motor connections

How to Wire a High & Low Voltage Three-Phase Motor

Motor Wiring Installation Tips

That means it is not the standard type of motor you described. Either the star or the delta arrangement can be re-connected series or parallel for a two to one voltage ratio. Are you an Engineering professional?

The only way that I know of to operate at a different voltage with a six lead motor is to make the low voltage a delta connection and the high voltage a wye connection at the motor. Delta will have the three corner points of the high voltage connection connected internally and one common lead brought out. Well, it looks as though you are stuck with it being a V motor then, you won't have a lower voltage connection because that is already the low voltage connection i.

OT 6 lead three phase motor wiring
6 lead motor - Electric motors & generators engineering - Eng-Tips

6 lead single voltage motor

How to use an old six wire stepper motor and control it with an Arduino. Arduino Stepper Motor Tutorial How to use an old six wire stepper motor and control it with an Arduino. The company that made this motor is from Canada.

Motor Wiring Part 2

The technician giving me the wrong numbers threw me at first. Please take a look of the address recomended by dbair. Thank you for helping keep Eng-Tips Forums free from inappropriate posts.

Unfortunately, that conflicts with your statement that it was running on the higher voltage, right? We'll bring you the most relevant peer-to-peer conversations happening in the trade and tips and tricks to help you get the job done. Resources The function of a circuit breaker is to provide overload thermal and short-circuit magnetic protection to a circuit and its downstream components. The higher voltage connections are the same but the lower voltage connections are different. Click Here to join Eng-Tips and talk with other members!

  • The V is used in the mining industry.
  • It's all sorted out now and running fine.
  • If two wires are not on the same coil, you will measure an open circuit.
  • Join your peers on the Internet's largest technical engineering professional community.
  • The Volts current is the twice of V so you need double connection to support the twice of current.
  1. Best to find a source close to you.
  2. For this example that means we want to connect the orange and blue wires, and the white and red wires, we will ignore the gray wire and brown wire, because they have a smaller resistance.
  3. Thus, mechanical side is more subject for such failure.
  4. We're working with the pump people now to change the motors.

If you let me have the type and serial number I may be able to find out when it was made and who the original customer was via my Brook Crompton agent. When I measuring ohm any wire with red wire show half of resistance of any wire combination. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Any chance that motor came to you somehow via Brazil? One thing is for sure, the motor we have is definitely not the one that we were supposed to have purchased.

Dag S K, You must not have read his posting carefully where he showed his connections. The motor was specified to be or volts. Students Click Here Join Us! This could be a part winding start motor. This motor uses six wires.

Wye Configuration High Voltage

The easiest way to do this is with a simple multimeter. What we need to do is measure the resistance from one motor wire to another. By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies. It is in the low voltage connection pattern already, but it is rated for V. Your connection diagram is exactly the same as the motors we get in Australia.